OAM: Standardize switch location strings across fleet

Support #437: OAM: Standardize switch location strings across fleet

Added by Charles N about 18 hours ago. Updated about 2 hours ago.

Status:
New
Priority:
Normal
Assignee:
-
Start date:
08/12/2026
Due date:
% Done:

90%

Estimated time:

Description

Parent: #314

Problem

Switch SNMP location strings are inconsistent across the fleet:

Switch Current location
pfv-r5-core-01 SITER1-ServerRoom-SiteR-Pflugerville
pfv-r3-tor-mgmt-01 R3-ServerRoom-SiteR-Pflugerville
pfv-r3-tor-stor-01 (empty)
pfv-r6-mgmt-01 R1-Garage-SiteR-Pflugerville
subopi3 SITER, Pflugerville, United States

This makes LibreNMS and NetDisco location filtering messy and unreliable.

Proposed standard

PFV/<Area>/<Rack>

Location Use
PFV/Server-Room/R1 Rack 1
PFV/Server-Room/R2 Rack 2
PFV/Server-Room/R3 Rack 3
PFV/Server-Room/R5 Rack 5
PFV/Server-Room/R6 Rack 6
PFV/EE-Lab EE Lab
PFV/Art-Room Art Room

Proposed mapping

Switch New location
pfv-r5-core-01 PFV/Server-Room/R5
pfv-r3-tor-mgmt-01 PFV/Server-Room/R3
pfv-r3-tor-stor-01 PFV/Server-Room/R3
pfv-r6-mgmt-01 PFV/Server-Room/R6
pfv-rrinfra-rtr PFV/Server-Room/R2

Scope

  • User approves location standard
  • Apply via conman on each switch: snmp-server location PFV/Server-Room/Rn
  • Update LibreNMS device locations (auto-discovered from SNMP)
  • Update NetDisco device locations (auto-discovered from SNMP)
  • Update phpIPAM device locations

Notes

  • phpIPAM sections already structured this way (PFV > Server Room / EE Lab / Art Room)
  • Aligns with rack numbering in Discourse #304 (Proxmox Fleet Reference)